Thrubeam Type Laser Detection Sensor

IB series

CatalogsView Catalog

Sensor HeadIB-10

Specifications

Model

IB-10

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 300 mm11.81"

Measurement range

10 mm0.39"

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø0.1 mmø0.004"*2

Repeatability

5 µm0.20 Mil*3

Temperature characteristics

±0.1 % of F.S./°C (±10 µm0.39 Mil)*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +50 °C32 to 122 °F(No freezing)

相对湿度

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m6.6')

Weight

Approx. 220 g

*1The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50.
*2Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3When distance between transmitter and receiver is set to 300 mm11.81", and light is half-shielded at a position 150 mm5.91"from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4When distance between transmitter and receiver is set to 100 mm3.94"and full light is received.

Other Models