Separate Amplifier Type Air Flow Sensor
FD-V40 series
Sensor Head, Air/Nitrogen Detection Type, 50 L/minFD-A50
Specifications
Model |
FD-A50 |
|||
Type |
For air or nitrogen (N2) |
|||
Detection range |
1.5 to 50 L/min (std)*1 |
|||
Zero-cut flow rate |
1.5 L/min (std) |
|||
Fluid type |
Air, nitrogen (N2) |
|||
Detectable fluids |
Clean gas that does not contain dust or oil mist (When compressed air is used, air that conforms to ISO class of 1.1.2 through 1.6.2 is allowable)*2 |
|||
Detectable fluid temperature |
0 to +50 °C32 to 122 °F(No condensation, no freezing) |
|||
Connection bore diameter |
Rc (PT) 1/4 |
|||
Display power |
Flow rate indicator: Green LED (x4). Output indication: Red LED |
|||
Environmental resistance |
Pressure resistance |
1.0 MPa |
||
Applied pressure range |
-0.07 to 0.7 MPa |
|||
Ambient temperature |
0 to +50 °C32 to 122 °F(No freezing) |
|||
相对湿度 |
10 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 3 hours in each of the X, Y, and Z axis*3 |
|||
Shock resistance |
300 m/s2, 10 times in each direction of each of X, Y and Z axis, 60 times in total |
|||
Material |
Measuring pipe section : Aluminum, SUS303, SUS304, polyetherimide, Fluorocarbon rubber, SiliconPiping section : Diecasting aluminum alloy, Case: Polysulfon, PBT |
|||
Accessories |
Head connector x 1 |
|||
Weight |
约125克(包括uding 3-m connector cable) |
|||
*1Converted value assuming the integrated flow quantity under the conditions of 20 °C68 °Fat 1 atmospheric pressure 101.3 kPa. |
||||