Clamp-on Flow Sensor
FD-Q series
Multi-Sensor Controller, Expansion UnitMU-N12
Specifications
Model |
MU-N12 |
|||
Main unit/Expansion unit |
Expansion unit |
|||
Response time |
Depends on the connected sensor model*1 |
|||
Expansion units |
Up to 4 expansion units*2 |
|||
I / O |
Control output |
4 max., |
||
External input |
5 max。 |
|||
Analog output |
- |
|||
Protection circuit |
Protection against reverse power connection, |
|||
Power supply |
Power voltage |
24 VDC, ripple (P-P) 10% or less, Class 2 or LPS |
||
Current consumption |
55 mA or less (without load)*5 |
|||
Sensor |
Allowable sensor current |
150 mA or less |
||
N-bus |
Allowable passing |
900 mA or less |
||
Environmental resistance |
Ambient temperature |
-20 to +50 °C-4 to 122 °F(No freezing) |
||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case and dust cover: Polycarbonate |
|||
Weight |
Approx. 70 g |
|||
*1The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model. |
||||