Laser scan micrometer
LS-3000 series
Recommended Replaceable Products:High-speed optical micrometer - LS-9000 series
Contact Us:1-888-539-3623Inquiry form
Sensor HeadLS-3036
Specifications
Model |
LS-3036 |
|||
Type |
Standard |
|||
Applicable controller |
LS-3100/LS-3100D |
|||
Scanning head type |
Single-body |
|||
Measurement range |
0.3 to 30 mm |
|||
Smallest detectable object |
0.3 mm0.01" |
|||
Transmitter/receiver distance |
60 mm2.36" |
|||
Repeatability |
±0.3 µm±0.000012"(number of averaging measurements: 512) |
|||
Measurement accuracy |
±2 µm±0.000079"or less*1 |
|||
Laser scan rate |
400 scans/s |
|||
Laser scan velocity |
63 m206.7'/s |
|||
Display |
Minimum display unit |
0.1 µm |
||
Terminal block I/O |
Analog voltage |
±6 V, Output impedance: 0 Ω |
||
Control output |
SPST-NO Relay contact 250 VAC 2 A (resistive load) |
|||
Control input |
Non-voltage input (contact/solid state) |
|||
Light source |
Semiconductor laser, wavelength: 670 nm, output: 35µ, Class 1 laser product (JIS C6802) |
|||
Interface |
RS-232C |
Measurement data output and control output (baud rate: selectable between 75 and 19,200 bps) |
||
GP-IB |
Measurement data output and control output*2 |
|||
BCD |
Measured data output (8 digits)*2 |
|||
Rating |
Power voltage |
85 to 264 VAC, 50/60 Hz |
||
Power consumption |
40 VA or less |
|||
Environmental resistance |
Enclosure rating |
IP60 |
||
Ambient temperature |
0 to +40 °C32 to 104 °F |
|||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Weight |
0.8 kg |
|||
*1When a rod 10 mm0.39"in diameter is measured in a 2 x 20 mm0.08" x 0.79", 4 x 20 mm0.16" x 0.79", or 10 x 20 mm0.39" x 0.79"measuring area. |
||||